The water ow is low – M016
There may not be enough water ow through the heater to carry the heat
away from the heating elements. Heater start up will begin again after
about 1 minute.
Flow-Related Checks
Check for low water level, suction ow restriction (lters) closed valved, or
trapped air.
The water ow has failed* – M017
There is not enough water ow through the heater to carry the heat away
from the heating element and the heater has been disabled. After the ow
problem has been resolved you must press any
button to reset and begin the heater start up.
Flow-Related Checks
Check for low water level, suction ow restriction (lters) closed valved, or
trapped air.
The heater may be dry* – M028
Possible dry heater or not enough water in the heater to start it. The spa
is shut down for 15 minutes. Press any button to reset the heater start-up.
Flow-Related Checks
Check for low water level, suction ow restriction (lters) closed valved, or
trapped air.
The heater is dry* – M027
There is not enough water in the heater to start it. The spa is shut down.
After the problem has been resolved, you must clear the message to re-
start the heater.
Flow-Related Checks
Check for low water level, suction ow restriction (lters) closed valved, or
trapped air.